<LOGO>
FM Transmitter Measurement Report
Created: 2026-11-06 10-27-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 17144 20,2636
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,1 dBr 4,87 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 20,2636 Acquired: 2026.11.06 10.26.03 Total samples: 17144 Equivalent time: 0:14:17 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,4 dBr MIN: 3,1 dBr AVE: 4,87 dBr % above 12,2 dBr: 0,0 Last value: 5,7 dBr (2026.11.06 10.26.02) 10.12 10.14 10.16 10.18 10.20 10.22 10.24 10.26 0 2 4 6 Pm [dBr]